y of the most limiting nutrients to the population would be difficult.The development of highly sensitive electrochemiluminescence (ECL) immunosensors by using functional nanoparticles as signal amplifiers is a solution towards sensitive determination of many low concentration disease biomarkers. Herein, a sensitive aptamer-based, sandwich-type surface plasmon enhanced electrochemiluminescence (SPEECL) immunosensor was demonstrated for the detection of cardiac troponin I (cTnI), by means of aptamer conjugated CdS QDs and AuNPs as ECL luminophores and plasmon sources, respectively, in which Tro4 aptamer was used as a capture probe for cTnI and Tro6 aptamer as a detecting probe. The signal of the developed SPEECL system showed ~ 5-fold increment as compared to that of without AuNPs. Using this ECL platform for the detection of cTnI, a linear range and the limit of detection (LOD) were found to be 1 fg/mL - 10 ng/mL and 0.75 fg/mL, respectively.Tumor-derived extracellular vesicles (TEVs) have emerged as promising sources of diagnostic and prognostic biomarkers for nasopharyngeal carcinoma (NPC). However, the lack of high-sensitivity analytic methods for ultratrace membrane proteins on TEVs hamper their clinical application of TEVs. Herein, by combining aptamers that specifically bind to protein targets on TEVs, PCR-based exponential amplification and CRISPR/Cas12a real-time DNA detection, we developed a novel technique, termed the aptamer-CRISPR/Cas12a assay, to detect CD109+ and EGFR+ TEVs from cell lines and complex biofluids. The platform enables highly sensitive detection of CD109+ and EGFR+ TEVs at as low as 100 particles/mL with a linear range spanning 6 orders of magnitude (102-108 particles/mL), which was found to be sufficient to effectively detect TEV proteins directly in low-volume (50 μl) samples. Furthermore, clinical serum sample analysis verified that the combination of serum CD109+ and EGFR+ TEV levels yielded high diagnostic accuracy, with an AUC of 0.934 (95% CI 0.868-1.000), a sensitivity of 84.1% and a specificity of 85.0%, in discriminating NPC from healthy controls. Moreover, the dramatic decrease in both biomarkers in responders after radiotherapy indicated their potential roles in radiotherapy surveillance. Given that the aptamer-CRISPR/Cas12a assay rapidly and conveniently detects ultralow concentrations of CD109+ and EGFR+ TEVs directly in serum, it could be useful in NPC diagnosis and prognosis.Mercury ion (Hg2+) is considered to be one of the most toxic heavy metal ions and can cause adverse effects on kidney function, the central nervous system, and the immune system. Therefore, it is important to develop a fast and simple method for sensitive and selective detection of Hg2+ in the environment. This research proposes a portable electrochemical sensor for rapid and selective detection of Hg2+. The sensor platform is designed based on thymine acetic acid anchored with cysteamine-conjugated core shell Fe3O4@Au nanoparticles (Fe3O4@Au/CA/T-COOH) immobilized on a sensing area of a screen-printed carbon electrode (SPCE) with the aid of an external magnetic field embedded in a homemade electrode holder for ease of handling. In the presence of Hg2+, the immobilized thymine combines specifically with Hg2+ and forms a thymine-Hg2+-thymine mismatch (T-Hg2+-T). The resulting amount of Hg2+ was determined by differential pulse anodic stripping voltammetry (DPASV). Under optimal conditions, the sensor exhibited two wide linearities in a range from 1 to 200 μg L-1 and 200-2200 μg L-1 with the reliability coefficient of determination of 0.997 and 0.999, respectively. The detection limit (LOD) and the quantification limit (LOQ) were also determined to be 0.5 μg L-1 and 1.0 μg L-1, respectively. The sensor was further applied for determination of Hg2+ in water samples, a certified reference material and fish samples. The results were compared with flow injection atomic spectroscopy-inductively coupled plasma-optical emission spectroscopy (FIAS-ICP-OES) systems as a reference method. Results obtained with the proposed sensor were relatively satisfactory, and they showed no significant differences at a 95% confidence level by t-test from the standard method. Therefore, considering its fast and simple advantages, this novel strategy provides a potential platform for construction of a Hg2+ electrochemical sensor.Rapid and sensitive diagnosis of bacterial infections at early stage is of great significance for food safety monitoring as well as clinical treatment. Herein, we construct a surface-enhanced Raman scattering (SERS) nanoprobe based on M13 phages for the selective detection and inactivation of Staphylococcus aureus (S. aureus). https://www.selleckchem.com/peptide/bulevirtide-myrcludex-b.html M13 phage with specific S. aureus-binding heptapeptide displayed on the N-terminal of pIII protein is selected from phage display peptide library. The S. aureus-specific SERS probe is thus constructed by in situ growth of gold nanoparticles (AuNPs) on M13 phage surface, followed by modification with 5,5-dithiobis-(2-nitrobenzoic acid) (DTNB) as SERS active molecule. Upon the addition of this SERS probe, M13 phage selectively binds with S. aureus to induce anchoring of AuNPs on S. aureus surface, and the SERS probe-labeled S. aureus cells are collected by centrifugation for SERS detection. For the quantification of S. aureus, a linear range of 10-106 cfu mL-1 is achieved in aqueous medium. It is further demonstrated by spiking recovery in soft drinks. Furthermore, this SERS probe exhibits bactericidal capabilities towards S. aureus, which shows promising potential to serve as a multifunctional platform for simultaneous detection and inactivation of S. aureus.Anthropogenic CO2 emissions are contributing to global warming and ocean acidification. Rapid and accurate measurements of seawater carbonate chemistry are critical to understand current changes in the ocean and to predict future effects of such changes on marine organisms and ecosystems. Total alkalinity (AT) measurements can be used to directly determine the calcification rate, but they are time-consuming and require large sample volumes. Herein, we describe an automated and transportable flow-through system that can conduct continuous AT measurement using an ion sensitive field effect transistor (ISFET) - Ag/AgCl sensor and three different reference materials. The response time, stability, and uncertainty of our system were evaluated by comparing AT values of calibrated reference materials to those calculated by our system. Our system requires only small amounts of seawater ( less then 10 mL) and a short time per sample ( less then 5 min) to produce results with a relative uncertainty of less than 0.1% (approx.